Compact FACT

  • ODI
Compact FACT Image
Compact FACT Image

The FACT is a key enabling cable termination technology developed to extend the operational depth and significantly increase the reliability of cable terminations. The Compact FACT is designed specifically for 4-conductor cables, employing a smaller form factor for applications with space limitations. The modularized FACT technology completely isolates the cable elements from the pressure balanced dielectric fluid-filled splice chamber and ambient subsea pressure using a penetrator assembly.

 The FACT, which provides isolation of the cable elements using a penetrator assembly, eliminates cable-dependent design limitations and common mode/single point failures. The FACT penetrator assemblies may be terminated directly to atmospheric enclosures or pressure balanced dielectric fluid-filled splice canisters. The FACT penetrator assemblies have also been designed with modularity in mind and may be used with Teledyne ODI ancillary accessories to adapt to a wide array of interfaces.

Key Features:

  • Subsea cable terminations with four electrical circuits and a minimized footprint
  • Adapts to a wide array of interfaces
  • Max pressure 6,600 psi

Benefits:

  • The compact FACT is purpose-designed for applications with a smaller footprint, saving cost and complexity
  • 25 year life validated by testing and scientific methods
  • Employs a penetrator assembly to eliminate cable-dependent design limitations


Specifications

DetailsOperational Temperature-10°C to +50°C *
Storage Temperature-40°C to +60°C *
Max Test Pressure10,000 psi*
Max Operational Pressure6600 psi
Minimum Cable Diameter0.50 in (12.7 mm)
Maximum Cable Diameter1.00 in (25.4 mm)
Material:Titanium Gr 2 or 316L Stainless Steel (Nitronic 60 Housing)
Design Life25 Years
Number of Circuits4 max
Max Operational Current30 amps per circuit*
Max Operational AC Voltage1.8 kV
Max Operational DC Voltage3.3 kV
Insulation Resistance≥10 GΩ @ 1 kVDC*
Splice Resistance≤0.1 Ω per circuit
* Subject to cable performance
**5th circuit for drain wire ​

Applications

  • Production and Infield Umbilical termination
  • Drilling Controls
  • Installation/Workover Control Systems (IWOCS)
  • Umbilical splices
  • Buoy end terminations
  • Observatory Node Termination
  • Remote instrumentation​