Key Features:

  • ​Phased Array: Unique phased array transducer design delivers enhanced position accuracy at a reduced size, eliminates the need for speed of sound correction, and reduces susceptibility to biofouling.
  • Cost Saving: Field swappable phased array transducers
  • Versatile: Upgradeable to include Acoustic Doppler Current Profiling capability.
  • Ethernet Compatible: Plug-n-play with today's interfaces.
  • Extended Range: Optional XRT (Extended Range Tracking) delivers up to a 60% increase in bottom tracking range
  • Simultaneous Multiple Data Type Output Capability: Ethernet interface allows for simultaneous multiple PD data output via TCP and/or UDP.
  • Dynamic Commands Capability: Pathfinder accepts command changes during operation without the need to stop the ping cycle or operation of the DVL.
  • Bottom-Track High Resolution Velocity and Navigation Parameters Data Blocks: Aid in the velocity measurement resolution and quality information for use in an Ex-tended Kalman Filter (EKF) Inertial Navigation System (INS) solution.
  • Time of Validity Output: Delivers highly accurate coupling with an INS further improving resulting DVL aided INS position accuracy. 
  • Low Latency Trigger: Mitigates interference with other SONARs
  • Leak Detection and Health Monitoring: Provides early warning for potential issues​​

​​Specifications
​300 kHz
​600 kHz
Max Bottom Tracking Range
up to 420m with XRT option
up to 160m with XRT option

Min Bottom Tracking Range

0.3m
0.15m
​Long Term Accuracy
(Bottom Tracking)

±0.08% ±0.1 cm/s (<8 m altitude);
±0.3% ±0.1 cm/s (>8 m altitude)

±0.06% ±0.1 cm/s (<4 m altitude);
 ±0.2% ±0.1 cm/s (>4 m altitude)

​Max Water Profiling Range

150m
60m
​Long Term Accuracy
(Water Profiling)
±0.6% ±0.1 cm/s
±0.3% ±0.1 cm/s

Velocity Range

±17 m/s
±12 m/s
​Max Ping Rate
7 Hz
12 Hz

Beam Angle

30°
30°
​Standard Depth Rating (others may be available)
6,000 m
6,000 m
​Standard Sensors
Temperature, Leak Detection, Health Monitor, Dual-axis Digital Inclinometer
Temperature, Leak Detection, Health Monitor, Dual-axis Digital Inclinometer
Communications
Ethernet & RS232; optional RS422
Ethernet & RS232; optional RS422
​Average Power Consumption
11.8W5.4W